Purpose : Autism spectrum disorder (ASD) is associated with atypical visual processing (e.g. Simmons et al. 2010). Previous electrophysiology studies have indicated reduced electroretinogram b-wave amplitude in ASD (Ritvo et al. 1986, Creel et al. 1989). Huynh et al. (2006) report thicker retinae in males using optical coherence tomography (OCT). This is relevant given the known male bias in ASD, and also the ‘extreme male brain’ theory of ASD (Baron-Cohen et al. 2005). However, the only study to investigate retinal structure in ASD reported reduced retinal thickness at the optic nerve head in their autism subgroup (n=11) (Emberti et al. 2013). Methods : Right eye retinal thickness was analysed using the Heidelberg Spectralis SD-OCT in 29 children with ASD (mean (±sd) age 13.2±3 years; range 8-17 years; 24 male; 17 Autism and 12 Asperger’s diagnosis). SD-OCT measures consisted of line and central 3mm volume scans. Age-matched typically developing children acted as controls (n=64, mean age 12.4±2.6 years; range 8-17 years; 30 male). Supplementary measures included axial length (AL) (Zeiss IOLMaster) and visual acuity (VA) (Keeler crowded LogMAR). Results : Volume OCT measures were successful in 25 ASD participants (86%) and 58 controls (91%). The ETDRS grid was used to segment areas of retinal thickness for analysis. For the ASD group, mean overall retinal thickness measures at the different test locations were: central foveal subfield (CFS) 285.8±22.2µm, superior 354.2±18.3µm, inferior 352.2±17.3µm, nasal 356.5±17.8µm, temporal 341.4±17.0µm. For the control group, mean CFS 281.8±18.4µm, superior 351.0±13.7µm, nasal 352.3±13.8µm, inferior 347.4±12.9µm, temporal 336.3±13.9µm. There was no significant difference in retinal thickness between groups in any test location (p>0.15), or when male data were analysed (p>0.66). There was no significant association between VA or AL and retinal thickness in either group (VA; ASD F(5,19)=1.6, p=0.21; controls F(5,52)=1.4, p=0.25: AL; ASD F(5,19)=1.6, p=0.21; controls F(5,50)=1.9, p=0.11). There was no significant difference in thickness between ASD diagnostic categories (F(1,23)=1.3, p=0.27). Conclusions : Retinal thickness is comparable in ASD and control children and is not influenced by gender or ASD diagnostic category. These data do not support the hypothesis for either a reduction in retinal thickness indicating a neural deficit in ASD, nor increased thickness as a biomarker for ASD.
Original languageEnglish
Title of host publicationUnknown Host Publication
PublisherLippincott Williams and Wilkins
Number of pages4217
Volume57
Publication statusPublished online - Sept 2016
EventAssociation for Research in Vision and Ophthalmology - United States of America
Duration: 1 Sept 2016 → …

Conference

ConferenceAssociation for Research in Vision and Ophthalmology
Period1/09/16 → …

Keywords

  • autism spectrum disorder
  • retina
  • ocular coherence tomography (OCT)

Fingerprint

Dive into the research topics of 'Investigation of Retinal thickness using OCT in Autism Spectrum Disorder.'. Together they form a unique fingerprint.

Cite this